Turn capacitance and frequency into ohms with this capacitive reactance calculator: Xc = 1 / (2πfC), the magnitude of an ideal capacitor's impedance, at 60 Hz US mains, 50 Hz, kHz, MHz, GHz or rad/s. It also runs backward from a target Xc to the capacitance or frequency, and entering the volts across the part adds current and reactive power.
How to Use the Capacitive Reactance Calculator
Capacitive reactance (Xc) is the AC voltage across a capacitor divided by the current through it at a given frequency, in ohms. It falls as frequency or capacitance rises. To work it out with this capacitive reactance calculator:
- Pick what to solve for. Choose reactance from frequency and capacitance, or the capacitance or frequency that gives a target Xc.
- Set the frequency. US mains (60 Hz) is filled in. Use 50 Hz for UK, European or Indian supplies, kHz to GHz for audio and RF, or rad/s for angular frequency.
- Read the capacitance and unit off the part. Run capacitors are marked in µF (often MFD), small film and ceramic parts in nF or pF.
- Want the amps? Add a voltage. The RMS volts across the capacitor give the current it draws and its reactive power.
Capacitive Reactance Formula: Xc = 1 / (2πfC)
Xc is the reciprocal of 2πfC: a capacitor passes current only while its voltage changes, so a faster swing or bigger capacitor passes more current per volt.
- C = capacitance, in farads (F)
- f = frequency, in hertz (Hz)
- XC = capacitive reactance, in ohms (Ω)
Example: on a 60 Hz US circuit, a 10 µF blower motor run capacitor gives XC = 1 ÷ (2π × 60 × 0.00001) = 265.3 Ω.
- C = capacitance needed, in farads
- f = frequency, in hertz
- XC = target reactance, in ohms
Example: 100 Ω at 60 Hz needs 26.53 µF.
- f = frequency, in hertz
- C = capacitance, in farads
- XC = target reactance, in ohms
Example: a 1 µF capacitor reaches 1 kΩ at 159.2 Hz.
Capacitor Impedance and the 90° Current Lead
Current through an ideal capacitor leads the voltage by 90°, so its impedance is Z = 1 / (jωC) = −jXc, with ω = 2πf. Energy taken in one quarter cycle returns in the next: the capacitor draws current but uses no real power. Susceptance, the B in the results, is 1 / Xc in siemens. Xc itself is in ohms, which means I = V / Xc gives the current, as the Ohm's law calculator does for a resistor.
Capacitive Reactance Table for Common Capacitors: 60 Hz, 50 Hz, 1 kHz
| Capacitor | Typical use | XC (60 Hz) | XC (50 Hz) | XC (1 kHz) |
|---|---|---|---|---|
| 100 pF | RF tuning | 26.53 MΩ | 31.83 MΩ | 1,591.5 kΩ |
| 100 nF | IC decoupling | 26.53 kΩ | 31.83 kΩ | 1,591.5 Ω |
| 1 µF | Audio coupling | 2,652.6 Ω | 3,183.1 Ω | 159.2 Ω |
| 5 µF | Fan motor run | 530.5 Ω | 636.6 Ω | 31.83 Ω |
| 10 µF | Blower motor run | 265.3 Ω | 318.3 Ω | 15.92 Ω |
| 40 µF | Compressor run | 66.31 Ω | 79.58 Ω | 3.98 Ω |
Capacitor Reactance in US Electrical Work (NEC Article 460)
At 60 Hz, reactance turns a microfarad rating into amps. A 100 µF power factor correction capacitor has Xc = 26.53 Ω, so across 240 V it draws 9.05 A and supplies 2.17 kvar. On a 230 V, 50 Hz supply the same part has 31.83 Ω and draws 7.23 A. NEC 2023 (NFPA 70-2023) Article 460 covers installations like this. With 240 V, 60 Hz on the nameplate, 9.05 A is the rated current, and NEC 460.8(A) sets the conductor ampacity minimum at 135 percent of it, about 12.2 A; the wire size calculator turns that into a gauge. A bank's kvar rating goes straight to line current with the kVAR to amps calculator.
NEC 460.1 excludes capacitors that are part of other apparatus and meet that apparatus's requirements, so the run capacitor in a listed condenser or furnace follows the equipment's listing. On systems of 1000 V or less, NEC 460.6(A) requires residual voltage to fall to 50 V within 1 minute of disconnection. Many run capacitors have no bleed resistor, so with the power off, meter one and discharge it through a resistor before touching it.
The formula also checks a run capacitor under load: enter measured volts divided by amps as the target Xc and solve for capacitance. A 35 µF compressor capacitor reading 310 V across C and HERM with 4.1 A in the HERM lead gives 75.61 Ω and 35.08 µF, right on rating. The HVAC shortcut µF = (2,652 × A) / V is this formula at 60 Hz. UL 810 is the US safety standard for capacitors; internationally, IEC 60831-1 covers self-healing low-voltage power factor capacitors and IEC 60252-1 motor capacitors.
Common Capacitive Reactance Mistakes
- Reading MFD as millifarads. MFD means microfarad: 45 MFD is 45 µF. Choosing mF makes Xc 1,000 times too small.
- Putting ω where f belongs. 377 rad/s is 60 Hz; entered as hertz, it makes Xc 2π times too small. Pick rad/s.
- Mixing up 50 Hz and 60 Hz figures. Xc is 20 percent higher at 50 Hz, so a 60 Hz bank fed at 50 Hz delivers about 83 percent of its rated kvar.
- Adding Xc to resistance directly. They act 90° apart: 100 Ω of resistance in series with 100 Ω of Xc is 141.4 Ω of impedance, not 200 Ω.
Disclaimer: Results are for an ideal capacitor. Real parts vary with tolerance and temperature, and at RF or milliohm levels ESR and lead inductance take over. Install capacitors to NEC Article 460 as your authority having jurisdiction (AHJ) adopted it, and leave power factor correction and motor capacitor design to a licensed electrician or PE.
Frequently Asked Questions
What is capacitive reactance?
Capacitive reactance (Xc) is the current-limiting effect of a capacitor in an AC circuit, equal to 1 / (2πfC) ohms. Because the current into a capacitor is set by how fast its voltage changes (i = C × dv/dt), a higher frequency or a larger capacitance lets more current flow per volt, and that means lower reactance. A 4.7 µF capacitor on a 60 Hz circuit has 564.4 Ω of reactance, and the current through it leads the voltage by 90°.
What is the impedance of a capacitor?
The impedance of an ideal capacitor is Z = 1 / (jωC) = −jXc. Its magnitude equals the capacitive reactance, and the −j marks the 90° lead of current over voltage, so a 100 nF capacitor at 1 kHz has an impedance of 1,591.5 Ω at −90°. A real capacitor adds its equivalent series resistance (ESR) and a little lead inductance. Its impedance is then close to ESR − jXc at low frequency, falls to a minimum near the ESR at its self-resonant frequency and turns inductive above it, which is the curve capacitor datasheets plot.
Does capacitive reactance increase or decrease with frequency?
It decreases. Frequency sits in the denominator of Xc = 1 / (2πfC), so doubling the frequency halves the reactance and halving it doubles the reactance. A 1 µF capacitor has an ideal reactance of 2,652.6 Ω at 60 Hz, 159.2 Ω at 1 kHz and 0.159 Ω at 1 MHz. At 0 Hz the reactance is infinite: once charged, an ideal capacitor blocks steady direct current. That inverse behavior is why capacitors block DC while passing audio and RF signals, and why a capacitor's current and kvar rise in step with frequency at a fixed voltage. Inductive reactance does the opposite and rises with frequency, as the inductive reactance calculator shows.
Does a capacitor have resistance?
A real capacitor does, in two forms: an equivalent series resistance (ESR) and a finite leakage resistance across the dielectric. Datasheets rate them as ESR or dissipation factor and as leakage current or insulation resistance. Its reactance is a different thing, although it is also in ohms (one volt per ampere, the SI unit listed in NIST SP 811) and limits current, as I = V / Xc. Resistance turns electrical energy into heat. Reactance stores it in the capacitor's electric field and hands it back twice per cycle, so the current is 90° out of step with the voltage and V × I is reactive power in var, not watts.
Get early access to OhmNexus Pro
Join the list for new calculators, guides and services, plus first access to our upcoming advanced and AI-assisted design tools. No spam; unsubscribe anytime.
Need more electrical tools?
View All Calculators