Inductive Reactance Calculator
This inductive reactance calculator finds XL = 2πfL for any coil from its inductance and frequency, or works back to the inductance or frequency for a target reactance. Frequency opens at 60 Hz for US mains; type 50 for most other grids, or change the unit for switch-mode and RF parts. Add a voltage to get the current and reactive power.
How to Calculate Inductive Reactance (XL)
Inductive reactance (XL) is the opposition an inductor offers to alternating current, in ohms: XL = 2πfL. To run this inductive reactance calculator, fill in the form from the top:
- Choose what to solve for: reactance by default, or L or f when you have a target XL.
- Enter the inductance and its unit, as marked on the part or datasheet.
- Check the frequency. It starts at 60 Hz for US mains. Most other countries run at 50; kHz to GHz suit switch-mode and RF parts, and rad/s takes ω directly.
- Add the coil voltage for current. RMS volts return I = V / XL, the same division as the Ohm's law calculator, plus reactive power in VAR.
- Press Calculate for the answer, a chart of XL against frequency and the SI working. Later edits refresh it.
Inductive Reactance Formula: XL = 2πfL
The inductive reactance equation, XL = 2πfL, gives ohms from hertz and henries. A coil's voltage is L times how fast its current changes (v = L di/dt), so more frequency or more inductance means more volts per amp: double either one and XL doubles. At 0 Hz it falls to zero. Capacitive reactance runs the opposite way, falling as frequency climbs: see the capacitive reactance calculator.
- XL = inductive reactance, in ohms (Ω)
- f = frequency, in hertz (Hz)
- L = inductance, in henries (H)
- 2πf = angular frequency ω, in rad/s
Example: a 1 mH line reactor in a US drive circuit sees 60 Hz: XL = 2π × 60 × 0.001 = 0.377 Ω.
- L = inductance needed, in henries
- XL = target reactance, in ohms
- f = frequency, in hertz
Example: a choke that should draw 1 A across 120 V, 60 Hz needs XL = 120 Ω and L = 120 ÷ (2π × 60) = 0.318 H.
Solved for frequency, f = XL / (2πL): a 47 µH switch-mode choke reaches 100 Ω at 338.6 kHz, and a 1.6 mH crossover coil reaches 8 Ω, a woofer's nominal impedance, near 800 Hz.
Inductor Reactance by Size: 60 Hz to 1 MHz
These are ideal values. "Past SRF" marks sizes above the self-resonant frequency of typical parts, where winding capacitance takes over and the coil acts like a capacitor.
| Inductance | 60 Hz | 50 Hz | 1 kHz | 1 MHz |
|---|---|---|---|---|
| 10 µH | 3.77 mΩ | 3.14 mΩ | 62.83 mΩ | 62.83 Ω |
| 100 µH | 37.70 mΩ | 31.42 mΩ | 0.628 Ω | 628.3 Ω |
| 1 mH | 0.377 Ω | 0.314 Ω | 6.28 Ω | 6,283.2 Ω |
| 10 mH | 3.77 Ω | 3.14 Ω | 62.83 Ω | Past SRF |
| 100 mH | 37.70 Ω | 31.42 Ω | 628.3 Ω | Past SRF |
| 1 H | 377.0 Ω | 314.2 Ω | 6,283.2 Ω | Past SRF |
What the Inductive Reactance Calculator Shows
Beyond XL, the result card lists:
- Impedance Z = +jXL. All reactance in an ideal part; +j marks the +90° angle.
- Current phase and power factor. The voltage peaks a quarter cycle before the current, so current lags by 90° (the ELI in "ELI the ICE man") and the power factor is 0.
- Reactive power Q = V2 / XL, in VAR. The magnetic field stores energy as current builds and returns it as current falls, so an ideal coil burns no real power.
- Susceptance B = 1 / XL, in siemens. It's the size of the inductor's admittance, Y = −jB, which adds directly across parallel branches.
Inductive Reactance on the Job: NEC Table 9 and Line Reactors
Every conductor run has XL. NEC 2023 (NFPA 70-2023) lists it in Chapter 9, Table 9 for 600 V cables at 60 Hz, three single conductors in conduit, in ohms to neutral per 1000 ft: 0.054 Ω for 12 AWG in PVC or aluminum conduit and 0.068 Ω in steel, whose magnetism adds inductance. On large conductors XL overtakes resistance (500 kcmil copper in PVC: 0.039 Ω against 0.027 Ω), and Table 9 Note 2 combines them into an effective impedance at the circuit's power factor. Sizing the conductor is a job for the wire size calculator.
Line reactors for variable-frequency drives are specified by percent impedance, commonly 3% or 5%. A 1 mH reactor carrying 22 A at 60 Hz drops 8.3 V, about 3% of a 480 V system's 277 V phase voltage. On a 230 V, 50 Hz supply (400 V line to line), XL falls by a sixth to 0.314 Ω and the same 22 A drops 6.9 V, still about 3%. NEC 470.11 requires a thermal barrier when a separately mounted reactor sits less than 305 mm (12 in.) from combustible material.
For international work, IEC 60050-131 defines reactance as the imaginary part of impedance, and IEC 60076-6 covers power reactors. NIST SP 811 sets out the SI units used here.
Common Mistakes When Calculating Inductive Reactance
- Losing the unit prefix. 4.7 mH typed as 4.7 H gives 1,771.9 Ω at 60 Hz instead of 1.77 Ω.
- Putting an AC coil on DC. Only winding resistance limits the current, so a relay or contactor coil can draw many times its rated current and burn out.
- Assuming L stays put. Past its rated current an iron-core choke saturates: L and XL drop, and current climbs faster than the formula predicts.
- Adding coupled coils. XL values sum in series and combine like parallel resistors only if the fields don't couple.
Disclaimer: These are ideal-inductor numbers. Real coils add winding resistance, saturation, tolerance and self-resonance; check critical values against the datasheet. On installation work, your authority having jurisdiction (AHJ) has the final say; involve a licensed electrician or PE.
Frequently Asked Questions
What are the formulas for capacitive and inductive reactance?
XL = 2πfL for an inductor and Xc = 1 / (2πfC) for a capacitor, with f in hertz, L in henries, C in farads and both answers in ohms. Frequency pulls them in opposite directions: double f and XL doubles while Xc halves. At 60 Hz, 100 mH gives 37.70 Ω and 10 µF gives 265.3 Ω. In series the two subtract, because their voltages sit 180° apart, and they cancel at the resonant frequency f0 = 1 / (2π√LC), 159.2 Hz for that pair. The capacitor reactance calculator handles the Xc side.
How do you calculate the impedance of an inductor?
Multiply the reactance by j: an ideal inductor has Z = jXL = j2πfL, an impedance magnitude equal to XL at a phase angle of +90°. A real inductor adds winding resistance R in series, which makes the magnitude √(R² + XL²) and the angle arctan(XL / R). Take a 100 mH choke with 20 Ω of winding resistance at 60 Hz: XL is 37.70 Ω, the impedance is 42.68 Ω, and current lags by 62.1° instead of 90°. Near its self-resonant frequency the winding capacitance takes over, and above it the part stops behaving as an inductor.
What is inductive reactance measured in?
Ohms (Ω), the same unit as resistance, since reactance is the volts across a coil per ampere through it. The units work out cleanly: a henry is a volt-second per ampere, so radians per second times henries leaves volts per ampere, which is the ohm. Inductance itself is in henries, usually written as mH, µH or nH, and frequency is in hertz. You can't convert ohms to henries without a frequency: at 60 Hz, each ohm of reactance corresponds to 2.65 mH, and at 50 Hz to 3.18 mH.
What is the resistance of an inductor?
It's the DC resistance (DCR) of the winding wire, the number an ohmmeter reads and datasheets list, and it's a separate quantity from XL. DCR turns current into heat (I²R) and barely changes at low frequencies. XL only holds energy in the magnetic field, so it dissipates nothing, yet it rises with frequency and vanishes at DC. That's why a meter reading on a choke or contactor coil comes out far below the coil's opposition to 60 Hz current, and why the term inductive resistance really means reactance. Skin effect and core loss push a real coil's AC resistance above its DCR at higher frequencies.
Get early access to OhmNexus Pro
Join the list for new calculators, guides and services, plus first access to our upcoming advanced and AI-assisted design tools. No spam; unsubscribe anytime.
Need more electrical tools?
View All Calculators